Co simulation

Simulation problems and their solution - II

Problem  While simulating a grid connected PV system using co-simulation among PSIM and SIMULINK i was getting error. The error stated that Algebraic state in algebraic loop containing 'SCMPPT_sensorless_v4_buckboost_ok/Product3' computed at time 0.0005 is Inf or NaN. There may be a singularity in the solution. If the model is correct, try reducing the step size (either by reducing the fixed step size or...

Continue Reading

dc-dc converter

On the topology for PV dc-dc converter

Solar PV modules are typically connected to an dc-dc converter for ensuring the operation at maximum available power. While the research work has shown us the possibilities of using different kinds of dc-dc converters, following three basic topologies are still widely used.  Solar PV modules are typically connected to an dc-dc converter for ensuring the operation at maximum available power. While the research...

Continue Reading

Grid connected PV inverter

My list of reference papers

Reading research papers is must for carrying out updated research that too in right direction. When I was stuck for almost two months on the design issues related to grid-connected PV systems I worked hard to get my issues resolved. While reading and reading and reading I read thesis reports, research papers and a lot of online articles. However, the following papers helped...

Continue Reading

Co simulation

Simulation problems and their solution - I

Problem I encountered a strange problem while co-simulation of a PV grid connected inverter. The problem was that for simulation time less than 2 sec, the simulation results were ok. For time more than 2.5 sec the results were bad. See these figures. ...

Continue Reading

Copyright statement

Copyright © 2015-2017 by Hadeed A Sher

All rights reserved. No part of this blog may be reproduced, distributed, or transmitted in any form or by any means, including photocopying, recording, or other electronic or mechanical methods, without my prior written permission. For permission requests, write to the blog author addressed “Attention: Permissions Coordinator,” at the contact form.


Disclaimer

This blog is about my PhD work and an archive to my engineering education. However, additional study material for the courses i teach and that i have studied is also archived here.
All the circuits in this blog are tested by myself under specific conditions. BE CAREFUL if you are experimenting them, the blogger and this blog are not responsible to any harm and or damage to yourself and your equipment.


Contact form

Name

Email *

Message *